GreenCalculusGet a free key

  1. Home
  2. Data
  3. UK DEFRA Well-to-Tank (WTT) Emission Factors 2026 — Complete Upstream Fuel Dataset
Last reviewed August 2026

UK DEFRA Well-to-Tank (WTT) Emission Factors 2026 — Complete Upstream Fuel Dataset

UK DEFRA well-to-tank emission factors dataset: upstream extraction, refining, transport and distribution factors for 31 fossil fuels, 19 bioenergy fuels and UK grid electricity generation — 164 factors in kg CO2e per kWh, litre, tonne, GJ, kg and cubic metre, flowing from the DEFRA conversion-factor workbook through the GreenCalculus MasterBrain and REST API/CSV to your Scope 3 Category 3 total.
MasterBrain v2026.284 · updated 6 Nov 2026
SourceDEFRA/DESNZ 2026
WorksheetsWTT-fuels, bioenergy, electricity
Parameters164 rows
GC ImplementationMasterBrain v2026.105
LicenceOGL v3.0

Well-to-tank (WTT) factors quantify everything that happens to a fuel before you burn it — extraction, refining, processing and delivery to the point of use. Burning the fuel is a separate, larger number. This page publishes the complete UK DEFRA 2026 WTT dataset: 164 factors covering 31 fossil fuels, 19 bioenergy fuels and UK grid electricity generation, every one traced to its cell in the published DEFRA workbook.

WTT is the factor most often left out of a corporate inventory. It is not optional under the GHG Protocol: the upstream emissions of every fuel you burn and every unit of electricity you buy belong in Scope 3 Category 3 (fuel- and energy-related activities not already in Scope 1 or Scope 2). For a road-freight or heating-heavy business it typically adds 15–25% on top of the combustion total.

WTT is not the same as your Scope 1 number

DEFRA publishes three related quantities and they are routinely confused. Tank-to-wheel (TTW, also called “fuel combustion”) is what comes out of the exhaust or flue — that is your Scope 1. Well-to-tank (WTT) is the upstream supply chain of that same fuel — that is Scope 3 Category 3. Well-to-wheel (WTW) is the two added together. Applying a WTW factor to a fuel you burn and reporting the whole thing as Scope 1 double-counts the upstream portion into the wrong scope; applying WTT and calling it Scope 1 is simply wrong. The factors on this page are WTT only.

What well-to-tank measures

A litre of diesel in your tank has already caused emissions before your engine turns over. Crude oil had to be extracted and transported to a refinery; the refinery consumed energy and vented process emissions; the finished product was moved by pipeline, ship and road to a depot and then to the forecourt. WTT is the sum of all of that, expressed per unit of the finished fuel.

The boundary DEFRA applies is cradle to point of use. It includes:

  • Extraction and production — drilling, mining, flaring, venting and fugitive losses at the wellhead or mine.
  • Processing and refining — the energy and process emissions of turning crude or raw gas into a usable product.
  • Transport and distribution — moving the fuel by pipeline, tanker, rail and road, including losses in transit.

It excludes the combustion itself, and it excludes the capital goods of the supply chain — the refinery, the pipeline and the tanker fleet are not amortised into the factor. Those belong in Scope 3 Category 2 if they are material to you.

Where WTT sits in the GHG Protocol

Every factor on this page maps to Scope 3 Category 3 — fuel- and energy-related activities not included in Scope 1 or Scope 2. The category exists precisely because the upstream half of your energy consumption is real, material and attributable to you, but is not an emission from a source you own or from electricity you purchased.

Which scope takes which part of the fuel lifecycle
Lifecycle stage What it covers Scope Factor source
Well-to-tank (WTT) Extraction, refining, transport of the fuel Scope 3 Cat 3 This page
Tank-to-wheel (TTW) Combustion in an asset you own or control Scope 1 DEFRA fuel combustion factors
Electricity generation Fuel burnt at the power station on your behalf Scope 2 Grid electricity factors
Electricity WTT Upstream of the fuel burnt at the power station Scope 3 Cat 3 This page
T&D losses Electricity lost in the grid before it reaches you Scope 3 Cat 3 T&D loss factors

A complete Category 3 figure is the sum of three separate elements: fuel WTT, electricity generation WTT, and transmission & distribution losses (both the T&D energy itself and its own upstream). This page supplies the first two.

Fossil fuel factors

All 114 fossil-fuel factors below, in kg CO₂e per unit of fuel. A dash means DEFRA does not publish that fuel on that basis — solid fuels have no litre or cubic-metre figure, and only the two natural-gas entries carry a cubic-metre basis. Read the calorific-value warning in gross versus net before using any per-kWh column.

UK DEFRA well-to-tank factors — fossil fuels (kg CO₂e per unit of fuel, upstream only)
Fuel kWh (gross CV) kWh (net CV) litre m³ tonne
Aviation spirit 0.06253 0.06582 0.61425 — 813.26357
Aviation turbine fuel 0.05153 0.05424 0.52817 — 661.79468
Burning oil 0.05153 0.05424 0.53078 — 660.82605
Butane 0.02524 0.02736 0.19765 — 344.30947
CNG 0.03789 0.04198 0.09289 — 530.77887
Coal (domestic) 0.05629 0.05925 — — 470.95724
Coal (electricity generation – home produced coal only) 0.05629 0.05925 — — 389.45704
Coal (electricity generation) 0.05629 0.05925 — — 390.06647
Coal (industrial) 0.05629 0.05925 — — 418.14964
Coking coal 0.05629 0.05925 — — 497.73658
Diesel (100% mineral diesel) 0.05913 0.06291 0.62409 — 752.0276
Diesel (average biofuel blend) 0.05816 0.06181 0.61101 — 733.64436
Fuel oil 0.05913 0.06291 0.69539 — 714.86545
Gas oil 0.05913 0.06291 0.62665 — 743.83524
LNG 0.06512 0.07214 0.41277 — 912.22817
LPG 0.02548 0.02736 0.18551 — 349.29282
Lubricants 0.09238 0.09828 — — 1116.83712
Marine fuel oil 0.05913 0.06291 0.69539 — 714.86545
Marine gas oil 0.05913 0.06291 0.62665 — 743.83524
Naphtha 0.04822 0.05076 — — 640.41464
Natural gas 0.03021 0.03347 — 0.3366 423.16368
Natural gas (100% mineral blend) 0.03021 0.03347 — 0.3366 423.16368
Other petroleum gas 0.02153 0.0234 0.11097 — 302.95197
Petrol (100% mineral petrol) 0.06253 0.06582 0.60664 — 815.93523
Petrol (average biofuel blend) 0.0614 0.0648 0.58094 — 777.33392
Petroleum coke 0.04053 0.04267 — — 402.62468
Processed fuel oils – distillate oil 0.08931 0.09501 0.9465 — 1123.49881
Processed fuel oils – residual oil 0.09364 0.09962 1.10125 — 1132.08149
Propane 0.02519 0.02736 0.1817 — 352.67018
Refinery miscellaneous 0.02923 0.03077 — — 348.98258
Waste oils 0.08895 0.09526 — — 1116.83712

Bioenergy & biofuel factors

All 49 bioenergy factors, in kg CO₂e per unit of fuel. These are not zero and must not be treated as such: the memo-item rule for biogenic carbon applies to combustion of the biomass, not to the energy and emissions of producing, processing and transporting it. Units differ from the fossil table because DEFRA publishes bioenergy on a GJ, kg, litre, kWh and tonne basis rather than on gross/net calorific value.

UK DEFRA well-to-tank factors — bioenergy & biofuels (kg CO₂e per unit of fuel, upstream only)
Fuel GJ kg litre kWh tonne
Avtur (renewable) 15.256 0.67052 0.53386 — —
Biodiesel HVO 16.445 0.72358 0.56439 — —
Biodiesel ME 11.933 0.44391 0.39508 — —
Biodiesel ME (from Tallow) 16.07836 0.59812 0.53232 — —
Biodiesel ME (from used cooking oil) 10.6742 0.39708 0.3534 — —
Bioethanol 28.909 0.77476 0.61516 — —
Biogas — — — 0.01851 102.85714
Biomethane (compressed) 15.797 0.77405 — — —
Biomethane (liquified) 23.903 1.17125 — — —
Biopropane 6.613 0.30684 0.15752 — —
Development diesel 23.32 1.0034 0.83338 — —
Development petrol 23.097 1.03129 0.76505 — —
Grass/straw — — — 0.01604 68.65
Landfill gas — — — 0 0
Methanol (bio) 37.597 0.74923 0.59414 — —
Off road biodiesel 11.933 0.44391 0.39508 — —
Wood chips — — — 0.00792 30.4
Wood logs — — — 0.01277 52.14
Wood pellets — — — 0.03744 177

Grid electricity factors

The upstream of the fuel burnt at UK power stations on your behalf, per kWh consumed. This sits alongside your Scope 2 generation figure, not instead of it, and it is separate again from transmission and distribution losses.

UK DEFRA well-to-tank factor — grid electricity (generation)
Carrier Unit WTT factor (kg CO₂e)
UK grid electricity — generation per kWh 0.03682

Gross versus net calorific value

Every per-kWh factor in the fossil table is published on two bases, and picking the wrong one is the most common quiet error on this dataset.

  • Gross calorific value (GCV), or higher heating value. Counts the latent heat recovered when water vapour in the combustion products condenses. This is the UK convention — gas bills, DEFRA reporting guidance and UK boiler efficiencies are all quoted gross.
  • Net calorific value (NCV), or lower heating value. Excludes that latent heat. This is the international and IPCC convention, and what most non-UK datasets use.

Because the same upstream emissions are divided by a larger energy denominator, the gross factor is always the smaller number. UK natural gas is 0.03021 kg CO₂e/kWh gross against 0.03347 net — an 11% difference that will silently misstate a gas-heavy inventory if the basis of your consumption data and the basis of your factor disagree.

Match the basis of your meter data

A UK gas bill is in kWh gross. If you pull that figure and apply a net factor because the spreadsheet column happened to be next to it, you overstate WTT by roughly 11%. Check which basis your energy data is on before choosing the column, and record the choice in your audit trail — an ISO 14064-3 verifier will ask.

Application — formulas & worked examples

WTT arithmetic is a single multiplication. The difficulty is never the formula; it is using the right factor on the right basis and putting the answer in the right scope.

WTT emissions (kg CO2e) = fuel quantity x WTT factor for that fuel and unit

Diesel in an owned fleet

A company burns 10,000 litres of 100% mineral diesel in vehicles it owns.

10,000 litres x 0.62409 kg CO2e/litre = 6,240.9 kg CO2e = 6.24 t CO2e  ->  Scope 3 Category 3

The combustion of that same diesel is a separate, larger figure and belongs in Scope 1. Reporting only the Scope 1 number leaves this 6.24 tonnes out of the inventory entirely.

Natural gas for heating

A site consumes 500,000 kWh of natural gas, metered on the UK gross basis.

500,000 kWh x 0.03021 kg CO2e/kWh (gross CV) = 15,105 kg CO2e = 15.1 t CO2e  ->  Scope 3 Category 3

Using the net-CV factor here instead would give 16.7 t — a 1.6 tonne overstatement created purely by a column choice.

Purchased electricity

A site imports 250,000 kWh from the UK grid.

250,000 kWh x 0.03682 kg CO2e/kWh = 9,205 kg CO2e = 9.21 t CO2e  ->  Scope 3 Category 3

This is the upstream of the fuel burnt at the power station, and it sits alongside — not instead of — the Scope 2 generation figure and the separate transmission & distribution loss element.

Calculators that use these factors

The worked examples above are automated in these GreenCalculus tools, which read this dataset live from the MasterBrain so results always reflect the current vintage:

Common reporting errors

  • Omitting WTT altogether. The most frequent error. A Scope 1 and Scope 2 inventory with no Category 3 line is incomplete, and it is the first thing an assurer checks once the obvious scopes reconcile.
  • Reporting WTT inside Scope 1. Upstream emissions are not from a source you own or control. They belong in Scope 3 whatever the fuel.
  • Applying a well-to-wheel factor and calling it Scope 1. WTW bundles the upstream in; splitting it back out afterwards is guesswork. Use the TTW factor for Scope 1 and the WTT factor here for Category 3.
  • Mixing calorific bases. Gross-basis consumption data against a net-basis factor, or the reverse. See gross versus net.
  • Treating bioenergy WTT as zero. Biogenic combustion CO₂ is a memo item; the emissions of growing, harvesting, processing and transporting the biofuel are not, and they are often substantial relative to the fuel’s own combustion figure.
  • Double-counting electricity. Generation WTT, T&D losses and the T&D losses’ own upstream are three distinct elements. Adding a blended “electricity lifecycle” factor on top of a Scope 2 figure usually counts at least one of them twice.

Methodology, boundaries & uncertainty

GWP basis. Every factor is published by DEFRA as an aggregate CO₂e value on the IPCC AR5 100-year basis. DEFRA does not publish a per-gas decomposition for upstream emissions, so no CH₄/N₂O split is available and no AR6 restatement is possible from the published data. The AR5 basis is preserved exactly as published rather than silently rebased — rebasing an aggregate CO₂e figure without the gas mix would be a fabrication.

Geography. These are UK-average factors reflecting the UK supply mix. They are appropriate for fuel purchased in the UK. For fuel purchased elsewhere the upstream mix — particularly the flaring and fugitive-methane profile of the producing region — can differ substantially, and a region-specific dataset is preferable where one exists.

Vintage. DEFRA/DESNZ publish annually in June. Factors change year to year as the supply mix and the underlying evidence base change, so a multi-year time series should apply the factor edition contemporaneous with each reporting year rather than restating history on the newest edition — unless you are deliberately recalculating a base year, in which case say so.

Uncertainty. Upstream factors carry materially wider uncertainty than combustion factors. Combustion is close to stoichiometry and well constrained; upstream depends on modelled estimates of fugitive methane, flaring rates and transport distances that are themselves uncertain and vary by source region. Treat WTT as the less precise half of a well-to-wheel figure.

Implementation & provenance chain

Every row on this page traces to a named cell in the published DEFRA workbook. Nothing is hand-transcribed: the tables above are generated directly from the same MasterBrain rows the REST endpoint serves, and the generator asserts that all 164 source keys render exactly once before the page is built.

Provenance chain
Stage What it is
Primary source UK Government GHG Conversion Factors for Company Reporting 2026 (DESNZ), worksheets WTT- fuels, WTT- bioenergy, WTT- UK electricity
Cell reference Each factor carries its workbook cell (e.g. 'WTT- fuels'!D75) in the source_ref field of the API response
Data layer GreenCalculus MasterBrain — canonical keyspace fuels.gbr.<fuel>.wtt.<unit>, version-stamped
Publication This page and the REST endpoint read the same rows; neither holds a private copy
Licence Open Government Licence v3.0 — free to reuse with attribution

Data access — REST API & CSV

The full 164-row dataset is available as a machine-readable REST endpoint and as a flat CSV download. Both serve exactly the rows shown in the tables above, versioned by MasterBrain edition and citable.

JSON — REST API
All 164 well-to-tank factors with keys, values, units, GHG scope/category and DEFRA workbook cell references. Cache-Control: max-age=3600; X-GC-Version header signals dataset updates.

/wp-json/greencalculus/v1/fuels-wtt-factors

Open API endpoint →

CSV — flat dataset
Flat CSV of all 164 rows (key, name, value, unit, gas, GWP set, GHG scope/category, source, note) — ready for spreadsheet import.

Click to generate ↓

Citation guidance

If you use this dataset in a published tool, report or academic work, cite the DEFRA primary source. The GreenCalculus compilation reference is optional but appreciated.

Department for Energy Security and Net Zero (2026). UK Government GHG Conversion Factors for Company Reporting 2026 — well-to-tank factors. London: DESNZ. Contains public sector information licensed under the Open Government Licence v3.0.

DEFRA/DESNZ primary citation

Cite this dataset (GreenCalculus compilation). A versioned, machine-readable snapshot of these factors is archived on Zenodo with a citable DOI:

Say, Jeremiah (2026). UK DEFRA well-to-tank (WTT) upstream fuel emission factors 2026 (machine-readable) (v2026.107). GreenCalculus. Zenodo. https://doi.org/10.5281/zenodo.21831008

GreenCalculus dataset DOI

Frequently asked questions

Well-to-tank covers everything that happens to a fuel before you burn it — extraction, refining, processing and delivery. Tank-to-wheel is the combustion itself, what leaves the exhaust or flue. Added together they are called well-to-wheel. The distinction matters for scope allocation, not just terminology: tank-to-wheel is Scope 1 for an asset you own, while well-to-tank is always Scope 3 Category 3 because those emissions occurred in someone else’s operations.

Scope 3 Category 3 — fuel- and energy-related activities not included in Scope 1 or Scope 2. This holds for the upstream of fuel you burn yourself and for the upstream of electricity you purchase. It never belongs in Scope 1, because the emissions did not occur at a source you own or control, and it never belongs in Scope 2, which covers only the generation of purchased energy.

Use whichever basis your consumption data is on. In the UK that is almost always gross — gas bills and UK boiler efficiencies are quoted on a gross calorific value basis, and DEFRA’s own reporting guidance follows suit. Net calorific value is the international and IPCC convention, so data from a non-UK system may well be net. Because the same upstream emissions are divided by a larger energy figure, the gross factor is always the smaller of the two: UK natural gas is 0.03021 kg CO₂e/kWh gross against 0.03347 net, an 11% gap.

No, and this is a common and material error. The rule that biogenic CO₂ is reported as a memo item applies to combustion of the biomass, not to its production. Growing, harvesting, processing and transporting a biofuel consumes energy and generates real emissions, and for some pathways the upstream figure is a large fraction of what the equivalent fossil fuel would emit in total. Biodiesel produced from used cooking oil, for example, still carries 0.3534 kg CO₂e per litre of upstream emissions.

Because the fuel burnt at the power station had its own upstream supply chain. Your Scope 2 figure captures the emissions of generating the electricity you consumed; it does not capture the extraction, refining and transport of the gas or coal that the generator burnt. That upstream portion is attributable to you in proportion to your consumption and belongs in Scope 3 Category 3, alongside — not instead of — the Scope 2 number.

They are separate elements and both belong in Category 3, but they must be calculated separately rather than merged into one factor. Generation well-to-tank applies to the electricity you actually consumed. Transmission and distribution losses apply to the additional electricity generated on your behalf but lost in the network, and those losses carry both a generation and an upstream component of their own. Collapsing all of it into a single “electricity lifecycle” multiplier is where double-counting usually creeps in.

They reflect the UK supply mix and are intended for fuel purchased in the UK. Upstream emissions vary considerably by producing region, mainly because flaring rates and fugitive methane losses differ, so applying a UK factor to fuel bought elsewhere introduces an error you cannot quantify from the published data. Where a region-specific upstream dataset exists for your supply, prefer it and document the choice.

DEFRA publishes well-to-tank factors only as an aggregate CO₂e value, on the IPCC AR5 100-year basis, with no per-gas decomposition. That means the gas mix behind each number is not disclosed and the figures cannot be restated onto an AR6 basis from the published data. GreenCalculus preserves the AR5 aggregate exactly as published rather than rebasing it, because rebasing a CO₂e total without knowing its gas mix would be a fabricated number rather than a conversion.

Version history

Substantive revisions to this dataset reference page
Version Date MasterBrain Summary
1.0 2026-08-06 v2026.105 Initial publication. Complete DEFRA 2026 well-to-tank dataset (164 factors): 31 fossil fuels, 19 bioenergy fuels, UK grid electricity generation. Scope mapping, gross/net calorific-value guidance, formulas and worked examples, 8-item FAQ, REST + CSV access.

Scroll to Top