What is the carbon footprint of a solar panel?
About 35.8 g CO₂e per kWh over its life for a modern rooftop system (IEA PVPS, 2023 data), against 820 g for coal. Almost all of it comes from making the panels and their parts; a panel repays its manufacturing energy in about a year.
A solar panel burns nothing, so its carbon footprint is almost entirely in the making: refining silicon, growing and slicing wafers, the glass and aluminium frame, the inverter, the mounting rails and the cabling. Spread over 30 years of electricity, that comes to a few tens of grams of CO₂e per kilowatt-hour — a small fraction of coal or gas — and it has fallen by about two thirds since the 1990s. This page shows the figure per kilowatt-hour and per panel, where it comes from, how long a panel takes to pay it back, and why published numbers differ.
The footprint per kilowatt-hour
The fair way to compare power sources is lifecycle emissions per kilowatt-hour: everything emitted to make, install, run and dispose of the system, divided by all the electricity it produces. The most current figure for solar comes from IEA PVPS Task 12, the International Energy Agency’s research programme on photovoltaic sustainability, in its 2023 update.
| Technology | g CO₂e per kWh | Notes |
|---|---|---|
| Mono-crystalline silicon (mono-Si) | 35.8 | PERC and TOPCon cells; module efficiency 20.9% |
| Multi-crystalline silicon | 43.6 | Module efficiency 18.0% |
| CIS / CIGS thin film | 35.5 | Thin film; module efficiency 17.0% |
| Cadmium telluride (CdTe) thin film | 25.2 | Thin film; lowest of the four |
Coal, gas, solar and wind medians from IPCC AR5 WGIII Annex III Table A.III.2 (rooftop range 26–60, utility 18–180); IEA PVPS figure from its 2023 update. Solar and wind values render live from MasterBrain.
A modern rooftop system is about 23 times lower than coal per kilowatt-hour and about 14 times lower than gas. It is higher than the median for onshore wind. The IPCC medians come from its 2014 report and compile older studies; newer, more efficient panels come in lower, which is why the IEA figure sits below them.
The footprint of one panel
Lifecycle studies report per kilowatt-hour, but the same IEA numbers can be turned into a figure per unit of capacity. The IEA’s reference system produces 976 kWh per kWp each year (degradation included) for 30 years:
| Unit | Lifecycle footprint | Of which the module |
|---|---|---|
| Per kWp of installed system | ≈ 1,048 kg CO₂e | ≈ 590 kg |
| Per 400 W panel, with its share of inverter and mounting | ≈ 420 kg CO₂e | ≈ 240 kg |
Nearly all of that is emitted once, before the panel produces anything. The module is just over half; the rest is the inverter (replaced once in the system’s life), the mounting structure, cabling and installation.
Where the emissions come from
The IEA’s supply-chain breakdown for a mono-Si system puts the module at 20.2 g of the 35.8 g per kWh — about 56%. The IEA’s model counts the electricity and heat used to make polysilicon, ingots, wafers, cells and panels, which is why the carbon intensity of the manufacturing country’s grid matters.
- Polysilicon and wafers — refining silicon to solar grade, growing ingots and slicing wafers, all of which use large amounts of electricity and heat.
- Cells and module assembly — cell processing, glass, the aluminium frame, encapsulants and the backsheet.
- Balance of system — inverter, mounting rails, cabling and installation, making up the other 44%.
- Operation — close to zero. Panels need occasional cleaning and an inverter replacement, but burn no fuel.
A solar panel’s emissions are paid up front and then barely added to. Every year it runs after paying them back is close to carbon-free electricity.
How it has fallen
The IEA tracks the same kind of rooftop mono-Si system, installed in Switzerland, over time:
IEA PVPS Task 12, 2023 update, time series for a residential rooftop mono-Si system (module efficiency 13.6% in 1996, 20.9% in 2023).
The fall was not smooth — the figure rose between 2007 and 2016 before dropping sharply — but module efficiency rose throughout: the same panel area now produces about half as much again as in 1996, so each kilowatt-hour carries less manufacturing. For the most recent change, from 2021 to 2023 systems, the IEA names its reasons: more efficient panels, less silicon lost when cutting wafers, and lower electricity and heat use in manufacturing, partly offset by a larger share of cell and wafer production in China and the wider Asia-Pacific region, which increased impacts.
How fast a panel pays back its carbon
There are two kinds of payback, and they answer different questions.
- Energy payback — how long the system takes to generate as much energy as went into making it. The IEA puts the non-renewable energy payback time of a mono-Si rooftop system in Europe at 1.0 year; CdTe thin film is 0.8 years.
- Carbon payback — how long it takes to avoid as many emissions as it embodies. That depends on the grid the solar power displaces: the cleaner the grid, the longer the carbon payback.
On the UK’s grid average of 0.131 kg CO₂e per kWh [GreenCalculus grid.gbr.electricity.location_based · DEFRA 2026 'UK electricity'!E25 · v2026.302], the example system below pays back its carbon in about 8 years. On the US average of 0.350 kg [GreenCalculus grid.usa.national.location_based · EPA EGRID 2023 'US23'!X3], about 3 years. Either way, the panel goes on producing for decades afterwards.
The money payback is a different number. For what a home system costs and saves in each US state, and how long it takes to pay for itself, use the Solar Panel Calculator.
Why published figures vary
Search for the carbon footprint of a solar panel and you will find figures from under 20 to over 100 g CO₂e per kWh — the IPCC’s utility-scale range alone runs from 18 to 180. Most of the spread comes from a few assumptions:
| Assumption | Effect |
|---|---|
| Where the panels were made | Silicon refining uses a lot of electricity, so panels made on a coal-heavy grid carry a higher footprint than those made on a clean one |
| Sunshine at the installation site | The same panel in Spain makes far more electricity than in Scotland, so its grams per kWh are lower; the IEA’s European reference is 976 kWh per kWp a year |
| Panel technology and efficiency | Thin-film CdTe is lowest; older multi-crystalline panels highest |
| Lifetime and degradation | A 30-year life is standard. The IEA notes that a 0.5% annual degradation rate instead of 0.7% lowers results by 3.2%; 0.9% raises them by 5.3% |
| Study age | Older studies assume less efficient panels and dirtier manufacturing, so they come out higher |
Worked example: a 4 kWp rooftop system
| Lifecycle footprint | 4 kWp × 1,048 kg/kWp = ≈ 4.2 t CO₂e |
| Annual generation (IEA reference yield) | 4 kWp × 976 kWh = 3,904 kWh |
| Emissions avoided per year, UK grid | 3,904 kWh × 0.131 = ≈ 511 kg → payback ≈ 8 years |
| Emissions avoided per year, US grid | 3,904 kWh × 0.350 = ≈ 1,365 kg → payback ≈ 3 years |
Over 30 years the system avoids around 15 t CO₂e in the UK and 41 t in the US, several times its own footprint. The calculation uses today’s grid averages; as grids get cleaner, each kWh of solar avoids less, so the real figures will be somewhat lower. The solar carbon payback calculator runs this for your own system and grid.
Frequently asked questions
Roughly 240 kg CO₂e for the module of a 400-watt mono-crystalline panel, or about 420 kg including its share of the inverter, mounting and installation. Those figures are derived from the IEA PVPS 2023 result of 35.8 g CO₂e per kWh for a European rooftop system producing 976 kWh per kWp a year for 30 years. Panels made on a coal-heavy grid come out higher.
It repays the energy used to make it in about a year in Europe, on the IEA’s figures. Carbon payback depends on the grid it displaces: about 3 years on the US average grid and about 8 years on the UK’s cleaner grid, for a typical rooftop system. Panels then keep producing for around 30 years.
No, wind is usually lower. The IPCC’s medians are 11 g CO₂e per kWh for onshore wind against 41 g for rooftop solar and 48 g for utility-scale solar. Both are far below coal, at 820 g, and gas, at 490 g. Modern solar panels have narrowed the gap: the IEA’s 2023 figure for a mono-Si rooftop system is 35.8 g.
Mostly because they use old data or quote the manufacturing footprint without spreading it over the panel’s output. The IEA’s own time series for a Swiss rooftop system fell from 121 g CO₂e per kWh in 1996 to 36 g in 2023 as panels became more efficient. Panels made on a coal-heavy grid also carry more carbon than those made on a cleaner one.
About 36 g CO₂e per kWh over its life for a modern mono-crystalline rooftop system in Europe, according to IEA PVPS (2023 update), against 820 g for coal and 490 g for gas. Per panel, that is roughly 420 kg CO₂e for a 400-watt panel with its share of the system, nearly all of it emitted during manufacturing.