Refrigerant & F-Gas GWP Values
51 refrigerant & f-gas gwp values held in the GreenCalculus MasterBrain, drawn from Ipcc Ar6; Eu F Gas Reg 2024. Values are read live from the data layer on every page build, so nothing here is re-typed and nothing can drift from the figures the calculators use. All are expressed in kg CO2e per kg leaked.
Where these factors are used
Refrigerant Leakage Methodology sets out how factors in this group are applied, and Scope 1 Refrigerant Leakage Calculator and Scope 1 F-Gas Inventory Aggregator draw on them directly. The published dataset these rows are drawn from is Refrigerant & F-Gas GWP Values, which carries a DOI for citation.
What this group contains
| Measure | Value |
|---|---|
| Factors | 51 |
| Publishers | 2 |
| Distinct units | 1 |
| Data version | MB v2026.110 · updated 2026-08-08 |
| Unit | Factors | Lowest | Median | Highest |
|---|---|---|---|---|
| kg CO2e per kg leaked | 51 | 0 | 962 | 14600 |
Figures are computed per unit and never blended: a median across different units would be arithmetically valid and physically meaningless.
What has changed
| Factor | Was | Now | Change | Edition |
|---|---|---|---|---|
| R-450A | 642.0 | 643.0 | +0.2% | MB v2026.69 · 2026-07-26 |
| R-437A | 1927.0 | 1930.0 | +0.2% | MB v2026.69 · 2026-07-26 |
| R-513A | 672.0 | 673.0 | +0.1% | MB v2026.69 · 2026-07-26 |
| R-407C | 1906.0 | 1908.0 | +0.1% | MB v2026.69 · 2026-07-26 |
| R-427A | 2395.0 | 2397.0 | +0.1% | MB v2026.69 · 2026-07-26 |
| R-417A | 2506.0 | 2508.0 | +0.1% | MB v2026.69 · 2026-07-26 |
| R-422D | 2915.0 | 2917.0 | +0.1% | MB v2026.69 · 2026-07-26 |
| R-407F | 1964.0 | 1965.0 | +0.1% | MB v2026.69 · 2026-07-26 |
| R-407A | 2261.0 | 2262.0 | +0.0% | MB v2026.69 · 2026-07-26 |
| R-422A | 3358.0 | 3359.0 | +0.0% | MB v2026.69 · 2026-07-26 |
| R-1234ze(E) | 7.0 | 1.37 | -80.4% | MB v2026.68 · 2026-07-26 |
| R-515B | 327.0 | 322.0 | -1.5% | MB v2026.68 · 2026-07-26 |
| R-134a | 1526.0 | 1530.0 | +0.3% | MB v2026.59 · 2026-07-18 |
Change history is reconstructed from every released edition of the data layer, v2025.13 to v2026.107. A factor absent from this table has held the same value throughout. A change shown as a dash moved off zero, where a percentage has no meaning.
Sources, citation & machine access
| Source | Publisher | Year | Licence |
|---|---|---|---|
| EU Regulation 2024/573 on fluorinated greenhouse gases | European Commission | 2024 | EU Official Journal — free use with attribution |
| IPCC Sixth Assessment Report (AR6) WGI | Intergovernmental Panel on Climate Change | 2021 | CC BY 4.0 |
Cite the upstream publisher for the values themselves. The reference below credits this compilation and, more usefully, pins the edition you read.
Say, Jeremiah (2026). Refrigerant & F-Gas GWP Values (MasterBrain v2026.110). GreenCalculus. https://greencalculus.com/factors/refrigerant-gwp-values/
Cite this factor group
Values change between editions. Quoting the MasterBrain version is what lets a reader resolve the exact number you used — see the change record above for factors in this group that have moved.
For a reference manager — BibTeX, then RIS:
@misc{greencalculus_refrigerants_2026,
author = {Say, Jeremiah},
title = {Refrigerant & F-Gas GWP Values},
year = {2026},
howpublished = {GreenCalculus},
note = {MasterBrain v2026.110},
url = {https://greencalculus.com/factors/refrigerant-gwp-values/}
}TY - DATA
AU - Say, Jeremiah
TI - Refrigerant & F-Gas GWP Values
PY - 2026
PB - GreenCalculus
ET - MasterBrain v2026.110
UR - https://greencalculus.com/factors/refrigerant-gwp-values/
ER - Every factor on this page is readable from the open endpoint. No key, no signup:
https://greencalculus.com/wp-json/greencalculus/v1/factors/refrigerantscurl -s "https://greencalculus.com/wp-json/greencalculus/v1/factors/refrigerants?limit=500"import requests
rows = requests.get("https://greencalculus.com/wp-json/greencalculus/v1/factors/refrigerants", params={"limit": 500}).json()["factors"]
print(len(rows), "factors in refrigerants")Or the same rows as a spreadsheet — every factor with its source, the edition it last changed in, and its own link:
https://greencalculus.com/wp-json/greencalculus/v1/factors-export?page=refrigerant-gwp-valuesBoth responses carry an X-GC-Version header, so a consumer can detect a new edition without diffing the payload. The CSV filename carries the edition too, so two downloads months apart do not collide.
All factors
| Factor | Value | Unit | Basis | Gas | Source | Last changed | Canonical key |
|---|---|---|---|---|---|---|---|
| HCFC-1224yd (CF3CF=CHCl) | 0.06 | kg CO2e per kg leaked | GWP-100 | HCFC | EU_F_GAS_REG_2024EU 2024/573 Annex II §1 (HCFC-1224yd). Source: Tokuhashi et al. 2018, J. Phys. Chem. A. | — | refrigerants.hcfc_1224yd |
| HCFC-1233xf (CF3CCl=CH2) | 1 | kg CO2e per kg leaked | GWP-100 | HCFC | EU_F_GAS_REG_2024EU 2024/573 Annex II §1 (HCFC-1233xf). Regulation states "default value, GWP not yet available". | — | refrigerants.hcfc_1233xf |
| HFC-1132 trans-1,2-difluoroethylene (CHF=CHF) | 1 | kg CO2e per kg leaked | GWP-100 | HFC | EU_F_GAS_REG_2024EU 2024/573 Annex II §1 (trans-HFC-1132 and isomers). Regulation states ">1, GWP not yet available" — stored as 1.0 floor. | — | refrigerants.hfc_1132_trans |
| Nonafluoro-(trifluoromethyl)pent-2-ene and isomers | 1 | kg CO2e per kg leaked | GWP-100 | HFC | EU_F_GAS_REG_2024EU 2024/573 Annex II §1 (nonafluoro-TFM-pent-2-ene). Regulation states "default value, GWP not yet available". | — | refrigerants.hfc_nonafluoro_tfm_pentene |
| 1,1,1,3,4,4,4-Heptafluoro-3-(trifluoromethyl)butan-2-one (CF3C(O)CF(CF3)2) | 0.29 | kg CO2e per kg leaked | GWP-100 | HFK | EU_F_GAS_REG_2024EU 2024/573 Annex III §1 (perfluoro butanone). Source: Ren et al. 2019, Environ. Sci. Technol. | — | refrigerants.hfk_perfluoro_butanone |
| PFC-4-1-14 (perfluoro-2-methylpentane, i-C6F14) | 7370 | kg CO2e per kg leaked | GWP-100 | PFC | EU_F_GAS_REG_2024EU 2024/573 Annex I §2 (PFC-4-1-14). Source: Droste et al. 2019, Atmos. Chem. Phys. | — | refrigerants.pfc_4_1_14 |
| Perfluorocyclopropane (c-C3F6) | 9200 | kg CO2e per kg leaked | GWP-100 | PFC | EU_F_GAS_REG_2024EU 2024/573 Annex III §2 (perfluorocyclopropane). Source: WMO 2018 Scientific Assessment of Ozone Depletion. | — | refrigerants.pfc_c_c3f6 |
| Perfluoro-N-methylmorpholine (C5F11NO) | 8800 | kg CO2e per kg leaked | GWP-100 | PFC | EU_F_GAS_REG_2024EU 2024/573 Annex III §2 (perfluoro-N-methylmorpholine). Source: REACH registration dossier (ECHA). | — | refrigerants.pfc_n_methylmorpholine |
| R-11 | 6230 | kg CO2e per kg leaked | GWP-100 | CFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (CFC-11 GWP-100) | — | refrigerants.r_11 |
| R-12 | 12400 | kg CO2e per kg leaked | GWP-100 | CFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (CFC-12 GWP-100) | — | refrigerants.r_12 |
| R-123 | 90 | kg CO2e per kg leaked | GWP-100 | HCFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HCFC-123 GWP-100) | — | refrigerants.r_123 |
| R-1233zd(E) | 4 | kg CO2e per kg leaked | GWP-100 | HFO | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HCFO-1233zd(E) GWP-100) | — | refrigerants.r_1233zd_e |
| R-1234yf | 0.501 | kg CO2e per kg leaked | GWP-100 | HFO | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFO-1234yf GWP-100). Aligned with existing gwp.HFO_1234yf.ar6_100. | — | refrigerants.r_1234yf |
| R-1234ze(E) | 1.37 | kg CO2e per kg leaked | GWP-100 | HFO | IPCC_AR6IPCC AR6 WGI Ch.7 Table 7.SM.7: HFO-1234ze(E) GWP-100 = 1.37 (confirmed against GHG Protocol IPCC GWP table v2.0 Aug-2024). CORRECTED v2026.68 from a prior 7 — the 7 is the EPA SNAP / equipment-nameplate regulatory figure, NOT an IPCC value (AR4 predates the compound; AR5 gives <1). | v2026.68 | refrigerants.r_1234ze_e |
| R-125 | 3740 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-125 GWP-100) | — | refrigerants.r_125 |
| R-1336mzz(Z) | 2 | kg CO2e per kg leaked | GWP-100 | HFO | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFO-1336mzz(Z) GWP-100) | — | refrigerants.r_1336mzz_z |
| R-134a | 1530 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-134a GWP-100). Aligned with existing gwp.HFC_134a.ar6_100. | v2026.59 | refrigerants.r_134a |
| R-141b | 860 | kg CO2e per kg leaked | GWP-100 | HCFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HCFC-141b GWP-100) | — | refrigerants.r_141b |
| R-143a | 5810 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-143a GWP-100) | — | refrigerants.r_143a |
| R-152a | 164 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-152a GWP-100) | — | refrigerants.r_152a |
| R-22 | 1960 | kg CO2e per kg leaked | GWP-100 | HCFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HCFC-22 GWP-100) | — | refrigerants.r_22 |
| R-227ea | 3600 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-227ea GWP-100) | — | refrigerants.r_227ea |
| R-23 | 14600 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-23 GWP-100) | — | refrigerants.r_23 |
| R-236fa | 8690 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-236fa GWP-100) | — | refrigerants.r_236fa |
| R-245fa | 962 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-245fa GWP-100) | — | refrigerants.r_245fa |
| R-290 (propane) | 0.02 | kg CO2e per kg leaked | GWP-100 | HC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (propane GWP-100) | — | refrigerants.r_290 |
| R-32 | 771 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-32 GWP-100). Aligned with existing gwp.HFC_32.ar6_100. | — | refrigerants.r_32 |
| R-404A | 4728 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-125/143a/134a 44/52/4) | — | refrigerants.r_404a |
| R-407A | 2262 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/125/134a 20/40/40) | v2026.69 | refrigerants.r_407a |
| R-407C | 1908 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/125/134a 23/25/52) | v2026.69 | refrigerants.r_407c |
| R-407F | 1965 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/125/134a 30/30/40) | v2026.69 | refrigerants.r_407f |
| R-41 | 135 | kg CO2e per kg leaked | GWP-100 | HFC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (HFC-41 GWP-100) | — | refrigerants.r_41 |
| R-410A | 2256 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/125 50/50) | — | refrigerants.r_410a |
| R-417A | 2508 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-125/134a/600 46.6/50/3.4) | v2026.69 | refrigerants.r_417a |
| R-422A | 3359 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-125/134a/600a 85.1/11.5/3.4) | v2026.69 | refrigerants.r_422a |
| R-422D | 2917 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-125/134a/600a 65.1/31.5/3.4) | v2026.69 | refrigerants.r_422d |
| R-427A | 2397 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/125/143a/134a 15/25/10/50) | v2026.69 | refrigerants.r_427a |
| R-434A | 3654 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-125/143a/134a/600a 63.2/18/16/2.8) | — | refrigerants.r_434a |
| R-437A | 1930 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-125/134a/600/601 19.5/78.5/1.4/0.6) | v2026.69 | refrigerants.r_437a |
| R-450A | 643 | kg CO2e per kg leaked | GWP-100 | HFO-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-134a/1234ze(E) 42/58) | v2026.69 | refrigerants.r_450a |
| R-452A | 2292 | kg CO2e per kg leaked | GWP-100 | HFO-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/125/1234yf 11/59/30) | — | refrigerants.r_452a |
| R-452B | 779 | kg CO2e per kg leaked | GWP-100 | HFO-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/125/1234yf 67/7/26) | — | refrigerants.r_452b |
| R-454A | 270 | kg CO2e per kg leaked | GWP-100 | HFO-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/1234yf 35/65) | — | refrigerants.r_454a |
| R-454B | 531 | kg CO2e per kg leaked | GWP-100 | HFO-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-32/1234yf 68.9/31.1) | — | refrigerants.r_454b |
| R-507A | 4775 | kg CO2e per kg leaked | GWP-100 | HFC-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-125/143a 50/50) | — | refrigerants.r_507a |
| R-513A | 673 | kg CO2e per kg leaked | GWP-100 | HFO-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-1234yf/134a 56/44) | v2026.69 | refrigerants.r_513a |
| R-515B | 322 | kg CO2e per kg leaked | GWP-100 | HFO-blend | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (constituents); ASHRAE 34 (composition R-227ea/1234ze(E) 8.9/91.1, assigned in addendum subsequent to 34-2019 Addendum f) | v2026.68 | refrigerants.r_515b |
| R-600a (isobutane) | 0.006 | kg CO2e per kg leaked | GWP-100 | HC | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (isobutane GWP-100) | — | refrigerants.r_600a |
| R-717 (ammonia) | 0 | kg CO2e per kg leaked | GWP-100 | NH₃ | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (NH3 — no radiative forcing assigned; GWP=0 by convention) | — | refrigerants.r_717 |
| R-718 (water) | 0 | kg CO2e per kg leaked | GWP-100 | H₂O | IPCC_AR6IPCC AR6 WGI Ch 7 (water vapour treated separately; GWP=0 by convention for direct emissions reporting) | — | refrigerants.r_718 |
| R-744 (CO2) | 1 | kg CO2e per kg leaked | GWP-100 | CO₂ | IPCC_AR6IPCC AR6 WGI Ch 7 Table 7.SM.7 (CO2 reference gas, GWP=1) | — | refrigerants.r_744 |
Last changed names the data-layer edition in which a factor last took a new value, reconstructed from every released edition since v2025.13. A dash means the value has not moved since tracking began — which is the answer to "is the figure I used last year still current?".
Common questions
51 factors. They are read live from the GreenCalculus data layer on every page build rather than re-typed, so the figures here are the same ones the calculators use. The upstream publishers are EU Regulation 2024/573 on fluorinated greenhouse gases and IPCC Sixth Assessment Report (AR6) WGI.
It names the measurement convention a factor is expressed on — GWP-100 here. Applying a factor on one basis to activity data collected on another is the most common way these numbers produce a wrong answer, and it is silent: the arithmetic still works. Check the basis matches your meter or invoice before using a value.
13 of the 51 factors here have been revalued at least once since tracking began, most recently in v2026.69. The Last-changed column names the edition each one last moved in, and a dash means the value has not moved at all — which is the answer to “is the figure I used last year still current?”.
Every row has its own link. Click the canonical key in the last column and the address bar will hold an anchor for that one factor, so a citation resolves to the number itself rather than to a table someone has to search. Quote the data-layer edition alongside it (currently v2026.107) — values change between editions, and the version is what lets a reader resolve the exact figure you used.
Yes. This group is readable from an open endpoint with no key and no signup: https://greencalculus.com/wp-json/greencalculus/v1/factors/refrigerants. Responses carry an X-GC-Version header so a consumer can detect a new edition without diffing the payload. Cite the upstream publisher for the values themselves.
Yes — these rows are drawn from Refrigerant & F-Gas GWP Values, which is deposited with a DOI. Cite the dataset when you are referencing the collection; use the per-row link above when you are referencing a single figure.